apollo y opa front

The APOLLO-Y Optical Parametric Amplifier has been developed to extend the tuning range of an ultrafast Ytterbium amplifier from the UV to the NIR. It is optimized to work with Ultrafast Systems’ spectrometers – Helios, Eos, Halcyone, etc. High stability and high efficiency are achieved through three-step amplification of a white-light supercontinuum, and all nonlinear crystal tuning, optical delay compensation, and wavelength separation is fully computer controlled.

This OPA has been designed as a capable yet easy-to-use pump source with the spectroscopist in mind. Its layout has been optimized to fit neatly alongside new or existing spectroscopy systems, minimizing the amount of bench space required. The inclusion of multiple frequency conversion schemes allows fully computer-controlled tuning of the output wavelength from 258 nm to 2600 nm, while collinear output from a single port reduces the need for external beam routing optics. The timing of the pulse output remains consistent across the whole wavelength tuning range.

Features & Specs

Features

  • Designed for amplified Ytterbium lasers

  • 25cm x 66cm (10” x 26”) footprint

  • Optimized for use with Ultrafast Systems’ delay lines and spectrometers

  • Single beam, single port output across the entire tuning range

  • Consistent output pulse timing across the entire tuning range

  • Fully tunable from 258 nm to 2600 nm with built-in SHF (515 nm), THF (343 nm), FHF (258 nm) option

Specifications

Mode

Wavelength range, nm

Conversion Efficiency at Peak* Rep. rate ≤5KHz

Conversion Efficiency at Peak** Rep. rate >5KHz

Polarization

FH Idler

258 - 320

1%

0.5%

H, V**

SH Signal

320 - 515

5%

4%

H, V**

SH Idler

515 - 630

3.5%

2%

V

Signal

630 - 1030

15%

10%

V

Idler

1030 - 2600

10%

5%

H, V**

FHF, THF, SHF

258, 343, 515

> 5%

> 5%

H, V**

* measured with 250 fs 100 uJ pump

** constant vertical polarization upon request

Pump Laser Requirements

Wavelength

~ 1030 nm

Pulse duration

100 - 400fs

Pulse energy

≥ 50µJ

Beam diameter

≤ 8mm

Stability

< 2% (pulse-pulse)

Brochures & Examples

Apollo-Y Brochure

We continuously improve our products and reserve the right to change products and specifications
at any time without notice. Images may or may not include optional equipment.

This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.

© 2002 – 2024 Ultrafast Systems, 8330 Consumer Ct, Sarasota, FL 34240, USA. All Rights Reserved.

Before contacting our support team we encourage you to check out our knowledge base

An answer to your question might already be there.

Send a message
to our sales team